Syllabus Edition

First teaching 2014

Last exams 2024

|

The Standard Hydrogen Electrode (DP IB Chemistry: HL)

Revision Note

Stewart

Author

Stewart

Expertise

Chemistry Lead

The Standard Hydrogen Electrode

  • The absolute value of a half cell potential cannot be measured, only differences in potential between pairs of half-cells.
  • For this reason, it is necessary to have a standard electrode against which all other half-cells can be compared
  • The standard hydrogen electrode is a half-cell used as a reference electrode and consists of:
    • Hydrogen gas in equilibrium with H+ ions of concentration 1.00 mol dm-3 (at 100 kPa)

2H+ (aq) + 2e ⇌ H(g)

    • An inert platinum electrode that is in contact with the hydrogen gas and H+ ions

  • It is given an arbitrary value of Eθ = 0.00 volts
  • When the standard hydrogen electrode is connected to another half-cell, the standard electrode potential of that half-cell can be read from a high resistance voltmeter
  • Standard Hydrogen Electrode, downloadable AS & A Level Chemistry revision notes

    The standard electrode potential of a half-cell can be determined by connecting it to a standard hydrogen electrode

    • In fact, the hydrogen electrode is rarely used in practice for a number of reasons:
      • The electrode reaction is slow
      • The electrodes are not easily portable
      • It is difficult to maintain a constant pressure
    • Once one standard electrode potential has been measured relative to the standard hydrogen electrode, it is not necessary to use the standard hydrogen electrode again
    • Any electrode whose electrode potential is known could be used to measure standard electrode potentials

    Measurements using the hydrogen electrode

    • If a hydrogen electrode is used to measure the electrode potentials of zinc and copper half reactions, the conventional cell diagrams would be:

    Pt 丨H2(g), 2H+(aq)  ∥  Zn2+ (aq), Zn (s)          Eθ = -0.76 V

    Pt 丨H2(g), 2H+(aq)  ∥  Cu2+ (aq), Cu (s)           Eθ = +0.34 V

    • Since the hydrogen electrode is always on the left, the polarity of the half cell measured is always with respect to hydrogen
    • The half reaction will therefore always be a reduction reaction, so that is why sometimes standard electrode potentials are termed standard reduction potentials
    • Tables of standard electrode potentials have been compiled ranking half cells from negative to positive values

    Table of standard electrode potentials

    Table of standard electrode potentials, downloadable IB Chemistry revision notes

    • The more negative the value; the better the half cell is at pushing electrons so the equilibrium lies to the left
    • This means the more negative the half cell; the better it can act as a reducing agent

    Exam Tip

    You might find this a helpful mnemonic for remembering the redox processes in cellsLio the Lion, downloadable AS & A Level Chemistry revision notes

    Lio the lion goes Roor! 

    Lio stands for ‘Left Is Oxidation’ and he is saying ROOR because that is the order of species in the cell diagram:

    Reduced 丨 Oxidised  ∥ Oxidised丨Reduced

    Pt 丨Fe2+(aq), Fe3+(aq) ∥ Cl2 (g), 2Cl- (aq) 丨Pt

    Did this page help you?

    Stewart

    Author: Stewart

    Stewart has been an enthusiastic GCSE, IGCSE, A Level and IB teacher for more than 30 years in the UK as well as overseas, and has also been an examiner for IB and A Level. As a long-standing Head of Science, Stewart brings a wealth of experience to creating Topic Questions and revision materials for Save My Exams. Stewart specialises in Chemistry, but has also taught Physics and Environmental Systems and Societies.